| Double Ended Shear Beam |
FSI-80260 |
|
|
| |
| |
|
| |
| |
| Applications |
- Truck Scale.
- Weigh Bridge.
|
|
|
|
Model 80260 -double ended shear beam Load Cell is ideally suited for truck, track, tank and hopper weighing applications. From its nickel exterior protection to its triple-seal gage area, this cell is designed to withstand the rigorous of harsh environmental conditions. |
| Features |
- 10Tf to 100 Tf Capacities.
- Low Profile Design.
- Electroless Nickel Plated High Alloy Tool Steel Construction.
- Complete Environmental Protection.
- Weigh Module - WM III Available Optionally for Cell Mounting.
|
|
| |
| Specification |
| Standard Capacities |
: |
10,15,20,30,40,50,75,100 - Tf |
| Excitation Voltage |
: |
10 VDC- Maximum
15 VDC |
| Nominal Output |
: |
3.0 mV/ V |
| Non - Linearity |
: |
< ±0.025% FSO |
| Hysteresis |
: |
< ±0.02% FSO |
| Non-Repeatability |
: |
< ±0.01% FSO |
| Creep (30 minutes) |
: |
< ±0.03% FSO |
| Zero Balance |
: |
±1.0% FSO |
| Input Resistance |
: |
770 ± 20 Ohms |
| Output Resistance |
: |
700 ± 7 Ohms |
| Insulation Resistance (50 VDC) |
: |
> 1000 Mega
Ohms |
| Safe Overload of Rated Capacity |
: |
150% |
| Ultimate Overload of Rated Capacity |
: |
300% |
| Allowable Side Load |
: |
50% |
| Side Load Discrimination |
: |
500:1 |
| Temp. Compensated Range |
: |
0-60 0C |
| Temperature Effect on Output |
: |
< 0.0015% FSO/ 0C |
| Temperature Effect on Zero |
: |
< 0.0020% FSO/ 0C |
| Deflection |
: |
< 0.5 mm at FSO |
| Finish & Construction |
: |
Electroless
Nickel Plated Tool Steel |
| Environmental Protection Class |
: |
IP68 |
|
|
|
|
| |
| Electrical Termination |
 |
|
| CAPACITY Kgf. |
A |
B |
C |
D |
E |
F |
G |
J |
R |
K |
Cable
Length Mtrs. |
| 10 to 45 |
260 |
216 |
72 |
64 |
61 |
52 |
25 |
6 |
25 |
13 |
20 |
| 75 to 100 |
292 |
254 |
86 |
76 |
70 |
60 |
38 |
10 |
38 |
20 |
20 |
|
|
|
|
|